High Temperature HP-1010-P-400

 

High Quality HP-1010-P-400 Image

High Quality HP-1010-P Image

 

HP-1010-P-400 Hot Plate Operating Specifications

 

Appropriate Substrates:

Two things are necessary for achieving good results.

1. Planar bottom surface

2. Substrate must be at least as thermally conductive as G10 epoxy glass laminate.

Substrate Limit:

9.5" x 9.5"

Temperature Range:

Ambient to 400ºC

Temperature Monitoring:

Digital PID controller

Heating Zones:

10" x 10.5" hot plate

Dimensions:

HP-1010-P:        Length = 12", Width = 11", Height = 2"

HP-1010-P400:  Length = 17", Width = 13", Height = 4.5"

Shipping Weight:

HP-1010-P:          6 lbs.

HP-1010-P400:    20 lbs

Power Requirements:

8A @ 115 Vac **************

220 Vac models  also available

Facilities Requirements:

Table mounted, no facilities requirements when operated in open area.

 

 

HP-1010-P-400 Hot Plate Features

 

Reflow Soldering / Curing:

Our STI family of hot plates are the SMT/Hybrid standard for reflow soldering, curing, and repair.   Bottom side heat technology allows for safe preheating and curing of substrates and SMT boards.

Thermal Shock:

The HP-1010-P-400 is an excellent preheat tools for repair work on substrates and components.  Our hot plates are ideal for curing epoxy and silicon encapsulations.

Hot Plate Conductive Surface:

The thermal conductive surface has a non-stick finish.  The bottom surface transfers the heat from the bottom up, heating the substrate and solder joints, rather than temperature sensitive components.

Simple Operation:

The HP-1010-P-400 is a self-contained plate.  They have a safety fuse, illuminated On/Off switch, a thermal switch with a temperature adjustment, and a heat "ON" lamp indicator.  These allow for safe operation in a lab or a production environment.

Easy to Profile:

The operation has a complete control and view of the hot plate  profile.  A single front panel control is used to adjust the temperature setting.

Repeatable Operation:

Profiling of the HP-1010-P-400 can be easily adjusted for different applications by adjusting the front panel control at the proper set point for the selected profile.